Introduction
D SERIES D 200:4L
D 200:4L Combines 20000 W of Flexible Power with the Latest Lake DSP, DANTE Digital Audio Networking and Advanced System Integrity Monitoring.
Features
-
20,000 Watt amplifier with 4 flexible output channels and up to 5,900 Watts channel output
-
Lake digital signal processing for unparalleled loudspeaker management and system control
-
Réseau audio numérique Dante à double redondance intégré 8×8 canaux avec prise en charge AES67
-
4 x 4,400 Watts into 2 Ohms, 4 x 5,000 Watts into 2.67 Ohms, 4 x 4,400 Watts into 4 Ohms, 4 x 2,300 Watts into 8 Ohms, 4 x 1,150 Watts into 16 Ohms, 4 x 3,300 Watts into Hi–Z 70 V, 4 x 4,700 Watts into Hi–Z 100 V
-
Proven and reliable Class–TD output stage with proprietary Intercooler high–efficiency cooling system
-
Rational Power Management (RPM) provides total flexibility to allocate available power across all 4 output channels
-
Best–in–class Power Factor Correction (PFC) with Current Draw Modelling reduces running costs and minimizes environmental impact
-
Under–Voltage Limiting (UVL) for continued operation during severe mains supply voltage drops
-
Dedicated on–board surveillance and load monitoring for mass notification applications
-
Redundant audio inputs and on–board system surveillance for voice alarm systems
-
CAFE (Configuring Amplifiers For the Environment) software for design, system planning, equipment planning, installation and commissioning
-
Control and monitoring integration with 3rd–party matrix systems including MediaMatrix and Q–Sys via dedicated interfacing software
-
Dedicated front–panel mute buttons for each amplifier channel with bicolour LED indication
-
4 canaux d’entrée analogiques ″Lake Class″ avec isolation de masse Iso–Float pour une distribution audio fiable
-
4 input channels of AES/EBU (AES3) digital audio supporting all standard sample rates up to 192 kHz with 24–bit resolution
-
2 Neutrik etherCON RJ–45 ports provide dual redundant Dante interfaces and remote configuration via Lake Controller and Dante Controller software
-
Balanced analog and digital audio inputs and amplifier outputs on plug–in Phoenix connectors
-
Detachable Neutrik powerCON cable rated at 250 V / 32 A with variety of wall plugs selectable on order
-
Removable dust filter grille for increased air circulation and simple maintenance
-
Rugged 2U rackmount chassis including rear support brackets for ease of installation
Technical sheet
Specification
General
Processing / Network |
Lake / Dante |
Number of amplifier channels |
4 |
Total burst power all channels (share among channels with RPM) |
20000 W |
Max output power (all channels driven)1
2 ohms |
4400 W |
2.67 ohms |
5000 W |
4 ohms |
4400 W |
8 ohms |
2300 W |
16 ohms |
1150 W |
Hi–Z 70 V |
3300 W |
Hi–Z 100 V |
4700 W |
Max output power single channel (all models)1
2 ohms |
4400 W |
2.67 ohms |
5900 W |
4 ohms |
4600 W |
8 ohms |
2300 W |
16 ohms |
1150 W |
Hi–Z 70 V |
3300 W |
Hi–Z 100 V |
4700 W |
Amplifier output modules (all models, all channels)
Peak output voltage |
194 V |
Max. output current |
67 A |
Rational Power Management (RPM) |
Regardless of model, any channel has potential to deliver the max single channel output power (1 channel on D 80:4, 2 channels on D 120:4) |
Default voltage limitation (can be lifted with RPM configuration) |
194 V |
Protection features |
Current Average Limiter (CAL), Very High Frequency Protection (VHF), Direct Current Protection (DC), Short Circuit Protection, Current–Clip Limiter, Voltage Clip Limiter, Temperature protection |
Amplifier platform
Inter Sample Voltage Peak Limiter (ISVPL) |
Configurable Peak voltage threshold and profile |
THD + N at 1 kHz and 1 dB below clipping |
< 0.04 % |
Pilot tone generation and analysis |
Yes |
Load impedance analysis |
Yes |
Frequency response (1 W into 8 Ohm, 20 Hz – 20 kHz) |
+/– 0.05 dB |
Internal Sample Rate / Data path |
48 / 96 kHz / 32 bit floating point |
Product propagation delay AES 96 kHz / analog input |
1.61 / 1.68 ms |
Lake processing
Loudspeaker processing |
Up to 4 modules of Classic/linear–phase/FIR crossover, EQ, delay, LimiterMax™ – peak and RMS limiters |
System tuning |
Group control with Raised Cosine™ MESA EG™ asymmetric filters |
Input redundancy / Matrix |
Automatic 4 level input redundancy / 4 input mixers |
System integration |
Comprehensive 3rd party protocol over UDP Ethernet |
Dante Audio Network
Dante I/O |
8 x 8 |
Network topology / redundancy |
Flexible topology / Supports daisy–chained and Dual redundant networks |
Sample Rates / Transport |
48, 96 kHz / Uni + Multicast |
Network latency |
0.25, 0.5, 1.0, 2.0, 5.0 ms |
AES Inputs
Inputs |
2 AES inputs (4 audio channels) |
Supported sample rates / resolution |
44.1, 48, 88.2, 96, 176.4, 192 kHz / up to 24 bits |
Sample rate conversion THD+N 20 Hz – 20 kHz unweighted |
0.0000003 |
Analogue inputs
Inputs |
4 high quality inputs with Iso–Float ground isolation |
Maximum input / digital reference |
+26 dBu / +21 dBu |
Sampling rate / Resolution |
96 kHz / 24 bit |
Input impedance balanced / unbalanced |
20 / 10 kOhm |
THD+N (typical at 1 kHz unweighted) |
0.0000022 |
THD+N (typical at 20 Hz and 20 kHz unweighted) |
0.0000033 |
Back panel Interface
Analogue inputs |
4 x Terminal block connectors analog input with +, – and ground |
AES Inputs |
4 x Terminal block connectors analog input with +, – and ground |
Output connectors |
4 x 2 pole Terminal block connectors rated at 1000 V / 76 A (exceeding amplifier capacity) Can take up to 16 mm2 (6 AWG) cables |
Ethernet Ports |
2 x EtherCon RJ45 100/1000 Base–T for the Lake Controller, Dante controller and/or DLM (3rd party protocol) |
Detachable mains cord |
Neutrik PowerCon rated at 250V/32A |
Front–panel user interface
System status indication |
3 x 3 colored LED. FRAME, TEMP, PSU for device status indication |
Channel status indication |
3 x 3 colored LED per channel. Status indication separated for channel LOAD, AMP, SIGNAL status |
Mute |
Per channel touch button for mute control and bicolored LED for indication |
Power |
Touch button for ON/STANDBY control and bicolored LED for power state indication |
Select |
Touch button and LED for bidirectional Device –Software select functionality |
Mains Power
Nominal voltage |
100 – 240 Volt AC 50 – 60 Hz |
Operating voltage |
70 – 265 V AC 45 – 66 Hz |
Mains wall plug |
Selectable on order CEE 7/7 “Schuko” 230 V / 16 A NEMA L5–30 “Twistlock” 125 V / 30 A NEMA 5–15P 125 V / 15 A (D 80:4 only) NEMA 5–20P 125 V / 20 A (D 120:4 only) NEMA 6–20P 250 V / 20 A AS/NZS 3112 230 V / 15 A (Aus/Nz) BS 546 230 V / 16 A (India) C–30P 125 V / 30 A (Japan) |
Power supply features
Soft start / Inrush power |
Yes/ Max 8 Ampere |
Power factor correction |
> 0.98 pour alimentation secteur > 400 W |
Regulated switch mode power supply (R.SMPS) |
Yes |
Breaker Emulation Limiter (BEL) |
Configurable current threshold and breaker profile |
BEL max current threshold |
32 A |
Power Average Limiter (PAL) |
Yes |
Under Voltage Limiter (UVL) |
Yes |
Mains undervoltage and overvoltage protection and mains glitch tolerance |
Yes |
Dimensions
Rack rail to rear panel |
L: 483 mm (19″), H: 88 mm (2 U), P: 424 mm (16″) |
Overall depth front–rear support |
D: 463 mm |
Weight
Weight |
16.5 kg (36 lbs) |
Finish
Finish |
Black painted steel chassis with grey painted steel front with detachable grille |
Downloads:
SOFTWARE:
CAFÉ Software (MAC) Version 1.5.6CAFÉ Software (Windows 32–bit) Version 1.5.6CAFÉ Software (Windows 64–bit) Version 1.5.6CAFÉ Software Release Notes Version 1.5.6Lake Controller Release Notes Version 8.1.3Lake Controller Software Version 8.1.3Lake LoadLibrary Version 5.9Q–SYS Plug–In Version 1.1.0
TECHDOCS:
A & E SpecificationsA & E Specifications, GermanBrochure EnglishBrochure GermanCurrent Draw & Thermal Dissipation EnglishData SheetData Sheet, GermanLake Controller Operation Manual EnglishLake Controller Operation Manual Version 1.7.0Operation Manual EnglishQuick Start Guide, All LanguagesQuick Start Guide, English